Ariston boiler showing an error code? Below are the official meanings by model line (Clas One, Genus One, Alteas One, Cares X, Clas FF, Egis Plus, BS II and Matis), plus safe pressure and reset steps taken from Ariston’s own manuals. Masterman repairs Ariston boilers in Tbilisi 24/7.
How Ariston error codes are structured
The first digit shows which part of the boiler has the fault: 1 – primary (heating) circuit, 2 – domestic hot water, 3 – internal electronics, 4 – external electronics, 5 – ignition and flame detection, 6 – air inlet / flue outlet, 7 – multi-zone, 8 – combustion control (ONE+). A “P” in the middle (5P3, 1P4, 6P1) means a warning, not a lockout. On many displays 5P3 looks like “SP3”. Source: Ariston Clas ONE Installation Manual, p.38.
Common Ariston error codes
| Code | Meaning (official manuals) |
|---|---|
| 101 | Overheating |
| 102 | Pressure sensor error (Clas FF, Genus ONE+, Alteas ONE+) |
| 103–107 | Insufficient circulation |
| 108 | Insufficient water pressure – fill the system |
| 109 | System pressure too high (over 3 bar) |
| 110 / 112 | Heating flow / return temperature probe open or short circuit |
| 114 | External temperature sensor |
| 116 | Floor thermostat contact open |
| 201 | DHW (or storage tank) temperature probe open or short circuit |
| 302 | Communication error between main PCB and display |
| 303, 305–307 | Main PCB error |
| 304 | Too many resets (more than 5 in 15 minutes) |
| 309 | Gas relay check failed (ONE+) |
| 501 | No flame detected – press RESET |
| 502 / 503 | Flame detected with gas valve closed |
| 504 | Flame lift |
| 5P1 / 5P2 | First / second ignition attempt failed (warning) |
| 5P3 (“SP3”) | Flame cut-off during operation (warning) |
| 601 | Flue gas sensor tripped (open-flue CF models) |
| 604 / 612 | Insufficient fan speed (612 on ONE+: fan speed above or below set value) |
| 607 | Air pressure switch closed while the fan is not running |
| 608 | Air pressure switch open while the fan is running |
| 6P1 / 6P2 | Air pressure switch slow to close / opens during fan operation (warning) |
| 111, 117, 308, A01, E34, H45 | Unknown – not found in the official Ariston manuals we checked |
Ariston Clas One / Clas System One codes
- 101 overheating; 103–107 insufficient circulation; 108 insufficient water, fill required; 109 pressure over 3 bar.
- 110 / 112 flow / return probe open or short; 114 external sensor; 116 floor thermostat open; 118 heating flow probe problem.
- 301 EEPROM error; 302 communication error; 303, 305–307 main PCB error; 304 more than 5 resets in 15 minutes.
- 501 no flame; 502 flame with gas valve closed; 504 flame lift; 5P1 / 5P2 1st / 2nd ignition failed; 5P3 flame cut-off.
- 610 main heat exchanger overheat; 612 insufficient fan speed.
Source: Clas ONE Installation Manual, pp.38–39; Clas One installation manual (IT, ariston.com).
Ariston Genus One and Alteas One codes
Most codes match Clas One (101, 103–107, 108, 110, 112, 501, 5P3). The ONE+ versions add:
- 102 pressure sensor error; 109 high primary circuit pressure; 114 external temperature not available.
- 147 pump locked; 148 pump dry running; 149 pump generic error; 151 pump electrical error; 1P4 filling needed (warning).
- 309 gas relay check failed; 313 low voltage fault; 315 pump communication error.
- 501 no flame (after 5 × 5P6); 502 / 503 flame with gas valve closed; 504 flame lift; 5P6 ignition failed; 5P5 low gas supply pressure (Genus One Net).
- 612 fan error (speed higher or lower than set); 8xx combustion control system, e.g. 804 decoupling clip-in required, 875 ionization control deviation, 877 actuators driver fault.
Source: Genus ONE+ WiFi Installation Manual, p.40; Alteas ONE+ Installation Manual, p.40; Genus One Net manual (ariston.com).
Ariston Cares X and Cares Premium codes
- 101 overheating; 103–107 circulation fault; 108 low pressure, fill required.
- 201 tank sensor open (Cares X System); 209 tank overheat (Cares X System).
- 301 display fault; 302 display–main PCB communication; 304 too many RESET presses.
- 501 no flame; 5P3 flame cut-off; 601 flue gas sensor tripped (CF model – the boiler retries ignition after 12 minutes).
- 607 air pressure switch ON with fan not running; 608 switch OFF with fan running; 6P1 / 6P2 switch delay / contacts open during normal fan operation.
- Cares Premium: 610 thermal fuse probe open; 612 insufficient fan speed.
Source: Cares X manual (ariston.com); Cares X CF manual; Cares Premium manual.
Ariston Clas (FF) codes
- 102 pressure sensor error; 201 DHW temperature probe open or short.
- 5P4 three flame cut-offs in one cycle.
- 604 insufficient fan speed; 607 air pressure switch closed permanently; 6P1 delay in air pressure switch closing; 6P2 air pressure switch close-open.
Source: CLAS FF Installation Manual, p.33.
Ariston Egis Plus codes
The display shows “Err” plus the code: 101 overheating, 103–107 circulation fault, 108 low pressure, 110 / 112 flow / return probe, 205 DHW probe open, 301 EEPROM, 302 PCB–display communication, 303–307 main PCB (304: more than 5 resets in 15 minutes), 501 no flame, 502 flame with gas valve closed, 5P1 / 5P2 ignition failed, 5P3 flame cut-off, 607 / 608 / 6P1 / 6P2 flue air pressure switch. Source: Egis Plus installation manual (Ariston Thermo Rus).
Ariston BS II and Matis – LED signals
BS II and Matis have no numeric codes. Faults are shown by combinations of the temperature LEDs (40–90) with a red or yellow LED. For example, on Matis a yellow LED with LEDs 40–50 lit means insufficient circulation. Read the combination against the table in your boiler’s manual. On lockout press RESET, no more than 5 times in 15 minutes. Source: BS II manual; Matis manual.
Ariston boiler pressure and reset – step by step
- Identify the error type. A safety shut-off (e.g. 108) clears by itself once the cause is removed. A lockout (e.g. 501) needs the RESET button.
- Check the pressure. With the system cold the gauge should read 0.6–1.5 bar. If 108 or 1P4 appears, top up with the filling tap under the boiler and close it at 1–1.5 bar.
- RESET no more than 5 times in 15 minutes. At the 6th attempt the boiler locks (304 on Clas One and similar models) and can be restarted only after disconnecting the electricity supply.
- If the code keeps coming back, switch the boiler and the external switch off, close the gas tap and call a qualified technician. Needing to refill often usually means a water leak.
Source: Clas One User’s Manual; Clas ONE Installation Manual, p.38; Genus One Net manual.