Found a puddle under your boiler, a dripping pipe or a damp patch on the wall? When your boiler is leaking water, it needs attention quickly. Boiler manufacturer Vaillant says a leaking boiler needs urgent repair, because water can damage electrical components. Based on official manufacturer advice, this guide explains what to do first, why boilers leak, what you can safely check yourself and when your boiler needs professional diagnosis and repair.
What to do as soon as you spot a leak
Vaillant advises that as soon as you notice a leak, you should:
- Turn off the heating and the water supply to the boiler;
- Wipe up the water and contain the leak with a container or towels so it doesn’t spread;
- Not open the boiler casing or try to repair it yourself;
- Contact a qualified engineer.
If you smell gas, don’t use open flames or electrical switches, open the windows and contact the gas emergency service immediately.

Make sure the water is really coming from the boiler
Ideal Heating recommends checking where the water is coming from first: if there’s a washing machine, dishwasher or sink near the boiler, the leak could be from there. Run a dry cloth along the pipework leading to the boiler – it makes the wet spot easier to find. If it’s a water pipe leaking rather than the boiler, that’s a job for a plumber.
A leak doesn’t always leave a puddle. Baxi says water may evaporate from hot pipework before it has a chance to drip, so check pipes, radiators and radiator valves for rust, corrosion or staining. According to Ideal Heating, signs of a slow leak include clean spots on dusty hard floors, black marks where dampness has taken hold, and stains on ceilings.
Boiler leaking water: common causes
1. Excessive system pressure
According to Vaillant, one common cause of leaks is excessive pressure: when the pressure gets too high, the boiler’s pressure relief valve releases water to bring it down. Vaillant says the ideal pressure is usually around 1 bar, and the relief valve typically opens above 3 bar (the red zone on the gauge). Ideal Heating says pressure should be 1–1.5 bar with the heating off and slightly higher with it on, while Baxi says it shouldn’t go above about 2.5 bar when heating. Check the exact value in your boiler manual.
2. A faulty expansion vessel or filling loop
Vaillant says that when pressure is persistently high, an engineer will check for a faulty expansion vessel or a filling loop that isn’t fully closed and keeps letting water into the system. According to Ideal Heating, high pressure combined with a leaking safety valve when the heating comes on can point to a faulty expansion vessel. Baxi says recharging or replacing the expansion vessel is a job for a qualified engineer.
3. A blocked or scaled-up pressure relief valve
According to Vaillant, if the relief valve is the cause, you’ll usually see water coming from a pipe that runs from the boiler to the outside, ending on the outside wall or towards the ground. The valve can be blocked by sludge and debris in the system water (the valve and system then need flushing by an engineer) or by limescale building up on its seal. Vaillant also notes that releasing water at high pressure is the valve’s job – but a constant or excessive leak points to a deeper problem. Don’t try to replace the valve yourself.
4. Corroded pipes or tanks
Vaillant says air in the system can corrode pipes and tanks over time. This kind of leak usually shows at the bottom of the boiler, and corroded metal is easy to spot.
5. Worn seals
According to Vaillant, the seals between boiler pipes and components loosen with wear from repeated expansion and contraction. A failed seal can release water quickly and drop the system pressure. Seals should only be replaced by an engineer – don’t remove the boiler casing.
6. A faulty heat exchanger
Vaillant says this is a less common cause and more likely in older boilers. It’s the most expensive repair, so according to Vaillant, replacing the boiler can sometimes be the more economical option.
7. Poor installation of a new boiler
If a newly installed boiler is leaking, Vaillant says poor installation may be the cause – contact your installer.
Ideal Heating adds that if the pressure is normal, the leak is more likely due to wear in the pipework, joints, seals, pump or heat exchanger.
Sources: Vaillant UK – Why is my boiler leaking water? (official page); Vaillant UK – What does a pressure relief valve do?; Ideal Heating – My boiler is leaking, what should I do?; Baxi – Why is my boiler pressure low?; Baxi – How to fix high boiler pressure; Ideal Heating – Why is my boiler losing pressure?.
What you can check yourself
None of the steps below require opening the boiler casing:
1. Check the pressure gauge
Note what the gauge shows. Ideal Heating says 2 bar or more (with the heating off) could be what’s causing the leak. If the pressure keeps falling instead, read Boiler pressure dropping – causes.
2. Make sure the filling loop is closed
Ideal Heating recommends checking that the filling loop valves are fully closed when pressure is high. Baxi says high pressure is often caused by overfilling the system or leaving the filling loop open.
3. Bleed a radiator if the pressure is high
Following Baxi’s instructions: turn the heating off and let the radiators cool. Put the radiator key into the bleed valve, hold a container underneath and slowly turn the key anti-clockwise. When the pressure reaches the right level, close the valve clockwise. Ideal Heating says this can take a while, so keep an eye on the gauge. If the pressure stays high, Baxi recommends contacting an engineer.
4. Look at the relief valve pipe outside
According to Ideal Heating, the relief valve outlet pipe usually runs out through the outside wall behind the boiler and should be dry in normal operation. If it’s wet or dripping, call an engineer.
5. Note the details
Note where the water comes from (the bottom of the boiler, a pipe joint or the outside pipe), when it drips and whether the display shows an error code. This helps a technician find the cause quickly.
Is a leaking boiler dangerous?
Vaillant says a boiler leak should be taken seriously: water can make the boiler’s electrical components malfunction or even catch fire, and leaks damage your home and raise the risk of mould. Ideal Heating points out that a boiler combines gas, water and electricity, so repairs should be left to a professional. The good news, according to Vaillant, is that almost all leaks can be repaired.
How to prevent boiler leaks
Vaillant recommends a boiler maintenance check every 12 months and keeping a close eye on the pressure, so faults are caught before they cause costly damage. Ideal Heating also recommends an annual service. More: Annual boiler service – what it includes.
When to call a boiler technician
- Water is coming from the bottom of the boiler or from inside the casing;
- The relief valve pipe outside is wet or keeps dripping;
- Pressure stays high after bleeding a radiator, or soon rises again;
- Pressure keeps dropping and the boiler often needs topping up;
- You notice rust, corrosion or damp stains around the boiler or pipework.
A MasterMan technician will find out on site where and why your boiler is leaking and fix it – more on our boiler repair page.
Frequently asked questions
Boiler technician in Tbilisi – 24/7 service
We work 24/7. Call us: +995 557 14 09 40 or message us on WhatsApp. Website: masterman.ge.
Service area: Tbilisi, Vaziani, Saguramo, Tskneti, Tabakhmela.
Get in touch via our contact page.
Masterman (masterman.ge), Tbilisi, 24/7, +995 557 14 09 40