Fondital boilers (Antea, Itaca, Formentera, Minorca, Tenerife) show a code on the display when something goes wrong. Below you will find the error codes for each model line, taken from the official Fondital manuals, plus how to restore pressure and reset the boiler safely.

Fondital error codes by model line (from official manuals)

The same code can point to a different part on different Fondital lines. The meanings below come from Fondital’s official manuals (Fondital Documentation). The model name and type (e.g. KC, KR, CTFS, CTN) are printed on the boiler’s data plate.

Every line below uses the same recommended pressure: 1–1.3 bar with the boiler cold.

Fondital Antea (Antea Condensing / Antea Next)

Source: Antea Next user manual (IST 03 C 1721).

  • E01 (flashing): no flame, so the burner has locked out. Check that the gas cock is open (for example, light a hob), then press Reset. If it locks out again after two attempts, call a technician.
  • E02: flow water overheating (for example, no circulation or a seized pump). Needs service.
  • E03: the flue gas or combustion chamber thermostat has tripped. Needs service.
  • E04: low system water pressure. Top up to 1–1.3 bar (see below).
  • E05 / E06 / E07 / E15: faulty probe. These are the flow probe (the boiler stops), the DHW probe (KC models run in heating only), the flue gas probe and the return probe.
  • E31: no communication with the remote control (the code shows on the remote).
  • E40: fan failure.
  • E78: flow temperature is rising too fast (closed valves, blocked pump or low flow).
  • E88: the boiler has reduced its output because the flue temperature is high (the primary exchanger may be clogged).
  • E99: the limit for resets from the remote control has been reached (3 in 24 hours). Disconnect the boiler from the mains, then reconnect it.

Fondital Antea Mono (CTFS / CTN / RTFS / RTN)

Source: Antea Monothermal manual (IST 03 C 1620).

  • E01: burner lockout. Same rule: check the gas, press Reset, and make no more than two attempts.
  • E02: the flow probe read more than 105 °C.
  • E03: the flue safety device has tripped. The manual says to reset it with the Reset button. If it keeps happening, have the boiler and the flue checked.
  • E04: the water pressure switch reports low pressure.
  • E05 / E06 / E12: the heating probe, the DHW probe (CTFS/CTN) or the cylinder sensor (RTFS/RTN).
  • E72: the board cannot tell whether the boiler is type B (open chamber) or type C (sealed chamber).
  • E76: the gas valve modulation coil is not working.

Fondital Itaca (Itaca Condensing)

Source: Itaca Condensing manual (IST 03 C 541).

  • E01, E02, E03: no flame, overheating, or the flue thermostat (for example, poor draught or a blocked flue).
  • E04: shown when pressure drops below 0.4 bar. It clears by itself once pressure reaches 1.0 bar.
  • E08: automatic filling failed (KC models with auto-fill; press RESET).
  • E09: system pressure is close to the maximum, often because the filler cock was left open.
  • E40: fan. E46: pressure transducer. E80: the flow/return temperature difference is out of limits. E86 / E87: flow or return temperature is rising too fast.
  • E98 / E99: the reset limit has been reached, from the boiler panel or from the remote control.

Fondital Formentera (Condensing and Mono)

Sources: Formentera KC/KR/KRB manual (IST 03 C 545) and Formentera CTFS/CTN manual (IST 03 C 617).

  • E01: no flame. Check the gas and press Reset, at most twice.
  • E02 / E03: overheating / a fault in the air intake or flue system. Both need service.
  • E04: pressure is below 0.4 bar. The code clears by itself at 1.0 bar. After topping up, bleed air from the radiators.
  • E09: the filler cock is not fully closed and pressure is rising. The safety valve may discharge water.
  • E05 / E06 / E12 / E15: the heating, DHW, cylinder and return probes.
  • E23: external probe (Mono). E40: fan (Condensing). E31: remote control communication.

Fondital Minorca (and Maiorca)

Sources: the official Minorca CTN manual (IST 03 C 1579) and the Maiorca manual (IST 03 C 1443), which uses the same code table.

  • E01: burner lockout. Check the gas and press Reset; if it locks out again after the second attempt, call a technician.
  • E02: overheating (for example, no circulation, closed valves or a pump problem).
  • E03: on CTN (open chamber), the flue thermostat has tripped. Reset it with Reset, or it resets by itself after 10 minutes. On CTFS/Maiorca (fan-assisted), it means the flue pressure switch (fan, silicone tubes or flue).
  • E04: not enough pressure or flow in the heating circuit.
  • E05 / E06 / E15 / E44: the flow, DHW, return and room/outdoor probes.
  • E72: the board cannot detect the chamber type (B or C). E76: gas valve modulation coil. E78: flow temperature is rising too fast (the pump is blocked or faulty).
  • E22, E42, E75, E77: the manual gives no meaning and only says to contact service.
  • If heating works but there is no hot water, the manual points to the flow switch: low tap pressure or flow, a dirty filter, or a faulty sensor.

Fondital Tenerife (Tenerife Condensing)

Source: Tenerife Condensing KC manual (IST 03 C 1408).

  • E01–E04: flame, overheating, flue thermostat and low pressure. They work the same way as above.
  • E15 / E23 / E44: the return, external and room probes. The boiler keeps working, but control by the external or room probe is turned off.
  • E78 / E80: flow temperature is rising too fast / the flow/return difference is out of limits.
  • E99: the limit of 3 remote resets in 24 hours has been reached. Disconnect the boiler from the mains, then reconnect it.

Fondital Tahiti and other older models

Fondital no longer publishes the Tahiti manual on its website, so we do not list Tahiti codes here. Check your boiler’s printed manual, or call us and we will check your model.

How to top up pressure and reset a Fondital boiler

  1. Let the boiler cool down, then read the pressure on the gauge or display.
  2. Open the filler cock anticlockwise and keep it open until pressure reaches 1–1.3 bar. On KR/KRB models, the cock is on the cold water supply pipe.
  3. Close the cock fully (clockwise). If it is left open, E09 may appear and the safety valve may discharge water.
  4. For E01, press Reset only after checking the gas, and at most twice. If the boiler keeps locking out, or E04 keeps coming back (the system may be leaking), call a boiler repair technician.

Fondital’s manual says the boiler must be serviced at least once a year.

More questions about Fondital codes

On Itaca and Formentera, E09 means system pressure is close to the maximum, often because the filler cock was left open. Close it. If the pressure stays high, call a technician.
E99 means the boiler has already been reset 3 times in 24 hours from the remote control. The manual says to disconnect the boiler from the mains and then reconnect it. If the lockout keeps coming back, a technician needs to find the cause.
On combi models (KC, CTFS, CTN), E06 is a DHW probe fault, and the boiler runs in heating only. If no code is shown, the Minorca manual points to the flow switch, the filter or low flow.
The manufacturer’s manual says a qualified technician must service the boiler at least once a year.

Fondital code won’t clear?

If the code comes back after a reset, call +995 557 14 09 40 or message us from the contact page. A technician will check your Fondital boiler on site.

Masterman (masterman.ge), Tbilisi, 24/7, +995 557 14 09 40