Italtherm boilers show an error code (E01, E10, E03 and so on) when the control board stops the boiler or detects a faulty part. The same code can mean different things on different Italtherm series, so this page lists Italtherm error codes by model, taken only from Italtherm’s official instruction manuals, together with what you can safely do yourself and when to call a technician. Codes not described in the official manuals are marked as unknown.
Common Italtherm error codes
| Code | Meaning |
|---|---|
| E01 | Flame went out or did not light (on a new installation: air in the gas line) |
| E02 | Overheat – safety thermostat tripped |
| E03 | Model-dependent: thermal fuse on condensing boilers; incorrect flue gas flow on traditional boilers |
| E05 | Heating flow temperature probe fault |
| E06 | Domestic hot water probe fault |
| E08 | Too many flame-loss lockouts (Time series: flue or air intake obstructed during operation) |
| E09 | Maintenance reminder – the boiler keeps working |
| E10 | Insufficient system pressure |
| E35 | Parasitic flame – flame detected when there should be none |
| E39 | Suspected freezing (probes at or below 0 °C after a power cut) |
City Class H K / H KR, City Top H, City Open H, City Box H
| Code | Meaning | What to do |
|---|---|---|
| E03 | Combustion group or flue thermal fuse tripped (overheating / flue gases too hot) | Reset does not clear it – the cause must be fixed and the fuse replaced. Call a technician. |
| E04 | Combustion control anomaly – gas valve powered without flame | One reset only; if it returns, call service. |
| E06 | Domestic hot water (DHW) probe fault (K models) | Probe and wiring check/replacement – call a technician. |
| E12 | Storage tank probe fault (H KR) | Probe and wiring check – call a technician. |
| E13 | Gas valve modulator disconnected | Gas valve circuit check – call a technician. |
| E15 | Return temperature probe fault | Probe/wiring check – call a technician. |
| E18 | Automatic filling in progress (City Top H, Open H, Box H) | Not a fault – clears by itself once pressure is restored. |
| E19 | Automatic filling not completed within 4 minutes | Check that the boiler’s water inlet tap is open; switch the power off for 30 seconds and back on. |
| E21 | 3 automatic fillings already made in 24 hours – probably a leak | Switch the power off for 30 seconds; if it returns, the leak must be found – call a technician. |
| E22 | Board software anomaly | Call service. |
| E23 | Mains frequency out of range (50 Hz ±5%) | Have the power supply checked. |
| E24 | Underfloor heating safety thermostat tripped | Let it cool and try Reset; if it returns, call a technician. |
| E25 | Automatic calibration required | Call service. |
| E26 | Gas valve did not open | Call service. |
| E29 | Flue or air intake duct possibly obstructed | Reset; if it returns, have the flue checked. |
| E45 | Flow and return probes swapped | Call service. |
| E47 / E48 / E49 | Maximum number of flame losses (combustion control / DHW / heating) | Call service. |
| E74 | Anti-legionella function error – temperature not reached in time (KR) | Call service. |
| E78 / E88 | Gas valve / modulator current out of range | Call service. |
| E79 | Fan control failure | Call service. |
| E90 / E93 | Flame signal inconsistent (momentarily / for more than 10 seconds) | Call service. |
| E92 | High system pressure (City Top H) | Call service. |
Sources (official Italtherm manuals): City Class H K, City Class H KR, City Class KR, City Top H, City Open H K, City Box H K.
Time K, Time KR, Time Max K, Time Micro, Time Compact
| Code | Meaning | What to do |
|---|---|---|
| E01 | Flame out or not lit; also incorrect combustion, phase/neutral reversed or condensate drain problem | Reset; with frequent lockouts have combustion, flue and siphon checked. |
| E03 | Combustion group or flue thermal fuse tripped | Part replacement needed – call a technician. |
| E06 / E12 | DHW probe (Time K, Time Micro) / storage tank probe (Time KR, Time Max K, Time Compact) | Call a technician. |
| E08 | Flue or air intake obstructed while the burner is running | Reset; if it returns, have the flue cleaned and checked. |
| E10 | Low system pressure and wrong SW6 (automatic filling) setting | A technician must check SW6 on the board. |
| E16 | Fan stopped or wrong speed | Reset; if it returns, call a technician. |
| E18 / E19 / E21 | Automatic filling in progress / not completed in 4 minutes / 3 filling cycles used up in 24 h | E18 clears by itself; on E19 check the water inlet tap; E21 points to a leak. |
| E22 | Stored data inconsistent | Power off for a few minutes; if it returns, call service. |
| E24 | Underfloor heating safety thermostat | Let it cool, reset; if it returns, call a technician. |
| E29 | Flue or air intake obstructed before burner ignition | Reset; if it returns, have the flue checked. |
| E33 / E34 / E46 | Configuration or wiring error | Reset; if it returns, call a technician. |
| E42 | System error / internal device / mains supply out of tolerance | Call service. |
| E43 | Return water too hot | Wait 20–30 minutes to cool, then reset. |
| E50 | Power supply out of tolerance 3 times in the last 5 minutes | Call service. |
| E62 | Communication error between display board and main board | Call service. |
| E91 | System pressure transducer fault | Call service. |
| E92 | System pressure too high (normally about 1 bar) | Lower the pressure (e.g. via a radiator bleed valve) and reset; if it returns, have the expansion vessel checked. |
| E93 | Filling stopped – water quantity limit reached | Check for leaks; power off for 30 s; if it returns, call a technician. |
| E98 | Clock/calendar data lost after a long power cut | Set the time and DHW program again. |
Sources (official Italtherm manuals): Time K, Time KR, Time Max K, Time Micro, Time Compact.
City Class F / FR, City Class C, City Class C NOx, Time Max F (traditional boilers)
| Code | Meaning | What to do |
|---|---|---|
| E01 | Flame went out or did not light | Reset (max 5 in 24 h); with frequent lockouts have combustion and flue checked. |
| E02 | Overheat – safety thermostat tripped | Reset; if needed wait 20–30 minutes and try again. |
| E03 | Incorrect flue gas flow (even momentary) | Reset; if it returns, have the flue, ducts and flue flow detection device checked. |
| E05 / E06 | Flow / DHW probe fault | Call a technician. |
| E08 | Maximum lockouts for no flame detection | Reset; if it returns, call a technician. |
| E10 | Insufficient system pressure (water pressure switch tripped) | Refill the cold system to 1.0–1.5 bar. |
| E11 | Flue pressure switch contact closed before the fan starts (F, FR, Time Max F) | Reset; if it returns, have the pressure switch checked. |
| E12 | Storage tank probe fault (FR, Time Max F) | Call service. |
| E15 | City Class C NOx: parameter 33 setting error (no return probe on this model) | Call service. |
| E42 / E50 | System error / power supply out of tolerance 3 times in 5 minutes | Call service. |
| E74 | Anti-legionella function error (FR) | Call service. |
| E44, E72 | Not described in the official user manuals for these models – meaning unknown | Do not keep resetting; contact a technician. |
On open-flue City Class C and C NOx boilers, E03 means flue gases are not leaving correctly through the chimney – ventilate the room and call a technician. If you smell gas, do not switch the boiler on.
Sources (official Italtherm manuals): City Class F, City Class FR, City Class C, City Class C NOx, Time Max F.
How to reset an Italtherm boiler and check the pressure
- RESET-type errors: press the Reset button. You get a maximum of 5 resets in 24 hours; after that the button has no effect.
- After 5 attempts: switch the power off at the external switch for 30 seconds. This gives 5 more attempts, but it usually will not solve the problem.
- SERVICE-type errors: these cannot be reset by the user because a component is faulty. You may switch the power off for 30 seconds; if the code comes back, call a technician.
- Exceptions: on E02 wait 20–30 minutes for the boiler to cool; E04 and E43 (H series) allow one reset only; E35 resets itself after 5 minutes; E09 can be hidden a maximum of 3 times.
- Pressure: 1–1.5 bar with the system cold (minimum 0.5 bar). When refilling, bring it to 1.0 bar (max 1.5 bar). The 3-bar safety valve may discharge if you overfill. On models with automatic filling, E18 is normal, while E19 or E21 need checking.
FAQ
Italtherm boiler repair in Tbilisi
If a code keeps coming back after a reset, or the display shows a SERVICE-type error, book a boiler repair technician. Call +995 557 14 09 40 or write to us via the contact page.