Italtherm boilers show an error code (E01, E10, E03 and so on) when the control board stops the boiler or detects a faulty part. The same code can mean different things on different Italtherm series, so this page lists Italtherm error codes by model, taken only from Italtherm’s official instruction manuals, together with what you can safely do yourself and when to call a technician. Codes not described in the official manuals are marked as unknown.

Common Italtherm error codes

Code Meaning
E01 Flame went out or did not light (on a new installation: air in the gas line)
E02 Overheat – safety thermostat tripped
E03 Model-dependent: thermal fuse on condensing boilers; incorrect flue gas flow on traditional boilers
E05 Heating flow temperature probe fault
E06 Domestic hot water probe fault
E08 Too many flame-loss lockouts (Time series: flue or air intake obstructed during operation)
E09 Maintenance reminder – the boiler keeps working
E10 Insufficient system pressure
E35 Parasitic flame – flame detected when there should be none
E39 Suspected freezing (probes at or below 0 °C after a power cut)

City Class H K / H KR, City Top H, City Open H, City Box H

Code Meaning What to do
E03 Combustion group or flue thermal fuse tripped (overheating / flue gases too hot) Reset does not clear it – the cause must be fixed and the fuse replaced. Call a technician.
E04 Combustion control anomaly – gas valve powered without flame One reset only; if it returns, call service.
E06 Domestic hot water (DHW) probe fault (K models) Probe and wiring check/replacement – call a technician.
E12 Storage tank probe fault (H KR) Probe and wiring check – call a technician.
E13 Gas valve modulator disconnected Gas valve circuit check – call a technician.
E15 Return temperature probe fault Probe/wiring check – call a technician.
E18 Automatic filling in progress (City Top H, Open H, Box H) Not a fault – clears by itself once pressure is restored.
E19 Automatic filling not completed within 4 minutes Check that the boiler’s water inlet tap is open; switch the power off for 30 seconds and back on.
E21 3 automatic fillings already made in 24 hours – probably a leak Switch the power off for 30 seconds; if it returns, the leak must be found – call a technician.
E22 Board software anomaly Call service.
E23 Mains frequency out of range (50 Hz ±5%) Have the power supply checked.
E24 Underfloor heating safety thermostat tripped Let it cool and try Reset; if it returns, call a technician.
E25 Automatic calibration required Call service.
E26 Gas valve did not open Call service.
E29 Flue or air intake duct possibly obstructed Reset; if it returns, have the flue checked.
E45 Flow and return probes swapped Call service.
E47 / E48 / E49 Maximum number of flame losses (combustion control / DHW / heating) Call service.
E74 Anti-legionella function error – temperature not reached in time (KR) Call service.
E78 / E88 Gas valve / modulator current out of range Call service.
E79 Fan control failure Call service.
E90 / E93 Flame signal inconsistent (momentarily / for more than 10 seconds) Call service.
E92 High system pressure (City Top H) Call service.

Sources (official Italtherm manuals): City Class H K, City Class H KR, City Class KR, City Top H, City Open H K, City Box H K.

Time K, Time KR, Time Max K, Time Micro, Time Compact

Code Meaning What to do
E01 Flame out or not lit; also incorrect combustion, phase/neutral reversed or condensate drain problem Reset; with frequent lockouts have combustion, flue and siphon checked.
E03 Combustion group or flue thermal fuse tripped Part replacement needed – call a technician.
E06 / E12 DHW probe (Time K, Time Micro) / storage tank probe (Time KR, Time Max K, Time Compact) Call a technician.
E08 Flue or air intake obstructed while the burner is running Reset; if it returns, have the flue cleaned and checked.
E10 Low system pressure and wrong SW6 (automatic filling) setting A technician must check SW6 on the board.
E16 Fan stopped or wrong speed Reset; if it returns, call a technician.
E18 / E19 / E21 Automatic filling in progress / not completed in 4 minutes / 3 filling cycles used up in 24 h E18 clears by itself; on E19 check the water inlet tap; E21 points to a leak.
E22 Stored data inconsistent Power off for a few minutes; if it returns, call service.
E24 Underfloor heating safety thermostat Let it cool, reset; if it returns, call a technician.
E29 Flue or air intake obstructed before burner ignition Reset; if it returns, have the flue checked.
E33 / E34 / E46 Configuration or wiring error Reset; if it returns, call a technician.
E42 System error / internal device / mains supply out of tolerance Call service.
E43 Return water too hot Wait 20–30 minutes to cool, then reset.
E50 Power supply out of tolerance 3 times in the last 5 minutes Call service.
E62 Communication error between display board and main board Call service.
E91 System pressure transducer fault Call service.
E92 System pressure too high (normally about 1 bar) Lower the pressure (e.g. via a radiator bleed valve) and reset; if it returns, have the expansion vessel checked.
E93 Filling stopped – water quantity limit reached Check for leaks; power off for 30 s; if it returns, call a technician.
E98 Clock/calendar data lost after a long power cut Set the time and DHW program again.

Sources (official Italtherm manuals): Time K, Time KR, Time Max K, Time Micro, Time Compact.

City Class F / FR, City Class C, City Class C NOx, Time Max F (traditional boilers)

Code Meaning What to do
E01 Flame went out or did not light Reset (max 5 in 24 h); with frequent lockouts have combustion and flue checked.
E02 Overheat – safety thermostat tripped Reset; if needed wait 20–30 minutes and try again.
E03 Incorrect flue gas flow (even momentary) Reset; if it returns, have the flue, ducts and flue flow detection device checked.
E05 / E06 Flow / DHW probe fault Call a technician.
E08 Maximum lockouts for no flame detection Reset; if it returns, call a technician.
E10 Insufficient system pressure (water pressure switch tripped) Refill the cold system to 1.0–1.5 bar.
E11 Flue pressure switch contact closed before the fan starts (F, FR, Time Max F) Reset; if it returns, have the pressure switch checked.
E12 Storage tank probe fault (FR, Time Max F) Call service.
E15 City Class C NOx: parameter 33 setting error (no return probe on this model) Call service.
E42 / E50 System error / power supply out of tolerance 3 times in 5 minutes Call service.
E74 Anti-legionella function error (FR) Call service.
E44, E72 Not described in the official user manuals for these models – meaning unknown Do not keep resetting; contact a technician.

On open-flue City Class C and C NOx boilers, E03 means flue gases are not leaving correctly through the chimney – ventilate the room and call a technician. If you smell gas, do not switch the boiler on.

Sources (official Italtherm manuals): City Class F, City Class FR, City Class C, City Class C NOx, Time Max F.

How to reset an Italtherm boiler and check the pressure

  1. RESET-type errors: press the Reset button. You get a maximum of 5 resets in 24 hours; after that the button has no effect.
  2. After 5 attempts: switch the power off at the external switch for 30 seconds. This gives 5 more attempts, but it usually will not solve the problem.
  3. SERVICE-type errors: these cannot be reset by the user because a component is faulty. You may switch the power off for 30 seconds; if the code comes back, call a technician.
  4. Exceptions: on E02 wait 20–30 minutes for the boiler to cool; E04 and E43 (H series) allow one reset only; E35 resets itself after 5 minutes; E09 can be hidden a maximum of 3 times.
  5. Pressure: 1–1.5 bar with the system cold (minimum 0.5 bar). When refilling, bring it to 1.0 bar (max 1.5 bar). The 3-bar safety valve may discharge if you overfill. On models with automatic filling, E18 is normal, while E19 or E21 need checking.

FAQ

On City Class H/KR and Time boilers, E03 means a thermal fuse has blown. It is a one-time device: the cause of the overheating must be fixed and the part replaced, so Reset does not help.
No. On Time and City Top/Open/Box H models, E18 means the boiler is refilling the system automatically. It usually clears within seconds. If E19 or E21 appears, the system needs checking.
A RESET-type error can be cleared with the Reset button (max 5 times in 24 hours). A SERVICE-type error points to a faulty component and must be fixed by a technician.
E10 means the system pressure is too low. With the system cold, refill to about 1.0 bar (max 1.5 bar). If the pressure keeps dropping, there is a leak; on Time models E10 can also mean the automatic filling setting (SW6) is wrong, which a technician must check.

Italtherm boiler repair in Tbilisi

If a code keeps coming back after a reset, or the display shows a SERVICE-type error, book a boiler repair technician. Call +995 557 14 09 40 or write to us via the contact page.