Strange letters and numbers on your air conditioner display – EL 01, EC 07, PC 00 or dF? Midea AC error codes fall into two groups: some simply show a mode or a reminder, while others point to a fault. In this article we explain, based on Midea’s official manuals, what the most common codes mean, what you can do yourself and when your AC needs a technician’s diagnosis and repair.

Important: code meanings differ by model and series. The tables below come from Midea’s official service manual for the Xtreme Inverter split series (MSAGB-09/12CRDN8, MSAGC-18CRDN8, R32 refrigerant). For any other model, always double-check your own unit’s manual.

How a Midea AC shows an error

According to Midea’s service manual, when the indoor unit detects an error, depending on the model it either shows a code on the display, flashes the running lamp a set number of times (the timer lamp may also light up or flash), or both.

Midea’s owner’s manual lists codes beginning with E(x), P(x), F(x) or EH(xx), EL(xx), EC(xx), PH(xx), PL(xx), PC(xx). Older or other series may show a short code such as E1 – check its meaning in your model’s manual.

Midea AC error codes – split air conditioner indoor and outdoor unit

Normal displays – not an error

Midea’s service manual lists these as “normal display, not error code”:

Code Meaning
dF Defrost
CL Filter cleaning reminder or Active Clean
nF Filter replacement reminder
FP Heating with room temperature under 8°C (8°C heating)
FC Forced cooling
AP Wi-Fi AP mode (app connection)
CP Remote switched off

According to the owner’s manual, CL appears after 240 hours of use as a reminder to clean the filter, and nF after 2,880 hours as a reminder to replace it. Both disappear after 15 seconds. To reset the reminder, press the LED button on the remote 4 times or the MANUAL CONTROL button 3 times. Midea recommends cleaning the filter once every two weeks.

dF means defrost. Midea says a low hissing sound during defrost is normal, and white mist may come out when the unit restarts in HEAT mode after defrosting – also normal. If your AC is not heating well, see: AC not heating – causes and what to check.

Midea AC error codes table

Below are the main indoor display error codes for the Xtreme Inverter series, according to Midea’s service manual:

Code Meaning
EH 00 / EH 0A Indoor unit EEPROM parameter error
EL 01 Indoor/outdoor unit communication error
EH 02 Zero-crossing signal detection error
EH 03 Indoor fan speed outside the normal range
EH 0b Indoor PCB / display board communication error
EH 60 Indoor room temperature sensor T1 open or short circuit
EH 61 Evaporator coil middle temperature sensor T2 open or short circuit
EC 51 Outdoor unit EEPROM parameter error
EC 52 Condenser coil temperature sensor T3 open or short circuit
EC 53 Outdoor room temperature sensor T4 open or short circuit
EC 54 Compressor discharge temperature sensor TP open or short circuit
EC 56 Evaporator coil outlet temperature sensor T2B open or short circuit
EC 07 Outdoor fan speed outside the normal range
EL 0C Refrigerant leakage detection
PC 00 IPM malfunction or IGBT over-strong current protection
PC 01 Over voltage or over low voltage protection
PC 02 Compressor top temperature, IPM high temperature or high pressure protection
PC 03 Low pressure protection
PC 04 Inverter compressor drive error
PC 08 Current overload protection
PC 40 Communication error between outdoor main chip and compressor driven chip

Source: Midea – Xtreme Inverter Series Service Manual (official PDF), Troubleshooting section.

EL 01 – indoor and outdoor units can’t communicate

According to Midea’s manual, EL 01 means the indoor unit cannot communicate with the outdoor unit. First step: switch off the power and restart the unit after 2 minutes. If the code stays, the manual calls for checking the wiring between the indoor and outdoor units and electrical measurements – a job for a technician.

EL 0C – refrigerant leak

EL 0C is the refrigerant leakage detection code. Midea’s owner’s manual says some units display “EL0C” or flash their LEDs when they detect a leak. According to the service manual, the T2 sensor and the system’s tightness are checked; if there is a leak, it is repaired and the refrigerant is recharged; if not, the system is checked for blockages.

EH 03 and EC 07 – fan speed

According to Midea, when the indoor (EH 03) or outdoor (EC 07) fan speed stays too low or too high for a certain time, the code appears and the AC turns off. The manual lists connection wires, the fan assembly, the fan motor and the main PCB as parts to check.

EH 60, EH 61, EC 52–EC 56 – sensors

These codes mean a specific temperature sensor is open or short-circuited. According to Midea’s manual, the error is triggered when the sensor’s sampling voltage is out of range. Checking the sensor and its connection requires measurement.

PC codes – compressor, voltage and pressure

The PC group covers outdoor unit protections. For example, PC 01 means an abnormal rise or drop in voltage – Midea’s first step is to check the power supply. PC 03 is low pressure protection: the outdoor pressure switch cuts off the system when low pressure falls below 0.13 MPa. PC codes involve outdoor electronics and the refrigerant circuit and should only be checked by a technician.

What you can do yourself

Midea’s owner’s manual (official PDF) recommends this sequence when error codes appear or indicator lamps keep flashing:

  • Wait about 10 minutes – the problem may resolve itself;
  • If not, disconnect the power, reconnect it and turn the unit on;
  • If the problem persists, disconnect the power and contact a service center.

Note: Midea says the unit has a 3-minute protection feature – it cannot be restarted within three minutes of being turned off. That’s not a fault. Always turn off the unit and disconnect the power before cleaning the filter. Don’t open the units, touch the wiring or tamper with the refrigerant circuit – it’s dangerous.

When to call an AC technician

  • The code remains after waiting 10 minutes and power-cycling;
  • EL 0C appears, or the AC cools/heats poorly;
  • A PC code appears (compressor, voltage, pressure);
  • The code keeps coming back or the AC switches itself off.

A MasterMan technician will find out on site why the code appeared and repair your AC. We also repair refrigerant leaks and refill refrigerant. More: AC repair and refrigerant refill. Planning a new unit? See AC installation.

Frequently asked questions

According to Midea’s service manual, dF means defrost and is a normal display, not an error.

On the Xtreme Inverter series, EL 01 is an indoor/outdoor unit communication error.

EL 0C means the AC has detected a refrigerant leak – the leak needs repairing before the refrigerant is refilled.

According to Midea, after cleaning the filter press the LED button on the remote 4 times or the MANUAL CONTROL button 3 times.

Wait 10 minutes, power-cycle the unit, and if the code stays, switch the AC off and call a technician.

AC technician in Tbilisi – 24/7 service

We work 24/7. Call us: +995 557 14 09 40 or message us on WhatsApp. Website: masterman.ge.

Service area: Tbilisi, Vaziani, Saguramo, Tskneti, Tabakhmela.

Get in touch via our contact page.

Masterman (masterman.ge), Tbilisi, 24/7, +995 557 14 09 40