Has F.22, F.28 or another code appeared on your boiler display and the heating stopped? This guide explains Protherm error codes based on the manufacturer’s official manuals: what each fault means, what you can safely do yourself and when your boiler needs professional diagnosis and repair.
The list is based on the official manuals for Protherm’s wall-hung gas boilers Panther Condens and Gepard Condens. On other or older models a code may mean something different, so always check your own boiler manual.
If you smell gas, don’t reset the boiler: avoid open flames and electrical switches, open the windows and contact the gas emergency service immediately.

How a Protherm boiler shows a fault
According to the Gepard Condens manual, an error code (F.xx) takes priority over all other displays, and if several faults occur at once they are shown in turn for 2 seconds each. The manufacturer says the boiler stores the last 10 error codes in its memory – this helps a technician find the cause.
The Protherm error codes you’re most likely to see
F.22 – Lack of water (low pressure)
According to the manual, F.22 is a safety shutdown due to lack of water: there is no water or too little water in the boiler. The manufacturer also lists a faulty water pressure sensor or a faulty pump/sensor cable as possible causes. On the Panther Condens, the pressure reading starts flashing at 0.5 bar or below, and at 0.3 bar the boiler switches off and logs F.22.
What to do: Protherm advises topping up the system using the filling tap until the pressure reaches the recommended 1–1.5 bar, then closing the tap. If the pressure drops often, contact a technician. More: Boiler pressure dropping – causes.
F.28 – Ignition failed
The Gepard Condens manual says that after three unsuccessful ignition attempts in a row, the boiler goes into fault mode and shows F.28. The service manual lists possible causes including closed or low-pressure gas, air in the gas line, a blocked condensate path, a faulty ignition system (electrode, lead, transformer) or gas valve, poor earthing, electronics, and a blocked air intake or flue.
What to do: make sure the gas tap is open, then press the reset button – the boiler will try to ignite again. The manufacturer says that if the problem remains after 3 reset attempts, you should contact a technician.
F.29 – Flame lost during operation
This code means the flame went out while the boiler was running and re-ignition failed. According to the manual, causes can include a temporary interruption of the gas supply, flue gas recirculation, a blocked condensate path, poor earthing, an ignition transformer misfire or a blocked air intake/flue.
F.20 – Overheating (temperature limiter)
F.20 is a safety shutdown triggered by the temperature limiter. The manufacturer lists these possible causes: a faulty temperature sensor (NTC), a blocked pump, air in the system, a faulty three-way valve or a wiring problem.
F.23 and F.24 – Circulation problems
F.23 means the temperature difference between flow and return is too high, and F.24 means the temperature is rising too quickly. For both, the manual lists a blocked or underperforming pump and air in the boiler; for F.24, also low system pressure.
F.54 – Gas pressure fault
F.54 appears together with F.28 or F.29. According to the manual, the cause is no or too low gas inlet pressure, or a closed gas shut-off valve. Check that the gas tap is open and whether other gas appliances in your home are working.
Other codes – all of these need a technician
- F.00 / F.01 – flow / return temperature sensor circuit open (sensor connector loose or sensor faulty);
- F.10 / F.11 – flow / return temperature sensor short circuit;
- F.26 – gas valve not working;
- F.27 – incorrect flame detection (moisture in the electronics, faulty flame monitor or leaking gas valve);
- F.32 – fan fault (including a blocked air intake or flue);
- F.49 – eBUS (controller) communication fault;
- F.61 / F.62 – gas valve control fault;
- F.63 / F.64 / F.65 – electronics fault (EEPROM, electronics/NTC, electronics overheating);
- F.68 – unstable flame signal;
- F.73 / F.74 – water pressure sensor signal out of range;
- F.83 – no temperature change detected when the burner starts (for example, too little water in the boiler).
The Gepard Condens manual advises contacting a service technician whenever the boiler shows an error code (F.xx). Don’t open the boiler casing yourself.
Sources (official Protherm manuals, PDF): Panther Condens – installation and maintenance manual (full error code table, Czech); Panther Condens – user manual (Slovak); Gepard Condens – user manual (Slovak).
What you can check yourself
According to the manufacturer’s user manuals, owners can do the following:
1. Check the pressure once a month
Protherm recommends checking the pressure on the display once a month while the boiler isn’t heating or making hot water. The recommended pressure is 1–1.5 bar.
2. Pressure too high
According to the Panther Condens manual, if the pressure reading flashes at 2.5 bar or more, reduce it by bleeding a radiator; if the problem keeps coming back, contact a technician.
3. Gas, power and valves
The manuals suggest checking that the gas taps (building and boiler) and the cold water tap are open, that power and the boiler itself are switched on, and that the heating or hot water temperature isn’t set too low.
4. Air in the system
If radiators heat poorly, the manufacturer advises bleeding them and then checking the pressure again; if the problem recurs, call a technician.
5. Water under the boiler
According to the Panther Condens manual, water under the boiler can be caused by a blocked condensate pipe – check it and clean it if needed. If water is leaking from the system or the boiler, close the cold water supply to the boiler and contact a technician. More: Boiler leaking water – what to do.
How to reset a Protherm boiler
According to the Panther Condens manual, when a fault is displayed, press the reset button and wait five seconds. If the fault is still there, contact a service technician. For F.28, the manufacturer mentions a maximum of 3 reset attempts. Don’t keep resetting the boiler over and over – if it keeps shutting down after a reset, read: Boiler keeps switching off – causes.
When to call a boiler technician
- F.22 keeps coming back and you constantly have to top up the water;
- F.28 remains after 3 reset attempts;
- The display shows F.20, F.23, F.24 or any of the “other” codes listed above;
- Water is leaking from the boiler or the system;
- Your boiler hasn’t been serviced for a long time – the Panther Condens manual calls for an annual inspection and maintenance every second year by a technician (see annual boiler service).
A MasterMan technician will find out on site why your Protherm boiler is showing a fault and fix it – more on our boiler repair page.
Frequently asked questions
Boiler technician in Tbilisi – 24/7 service
We work 24/7. Call us: +995 557 14 09 40 or message us on WhatsApp. Website: masterman.ge.
Service area: Tbilisi, Vaziani, Saguramo, Tskneti, Tabakhmela.
Get in touch via our contact page.
Masterman (masterman.ge), Tbilisi, 24/7, +995 557 14 09 40

Leave A Comment